VTP

Vertical Turbine Long Shaft Centrifugal/Axial Flow/Mixed Flow Water Pump

Technical Specifications

Pump Type Vertical Turbine Long Shaft Pump
Series VTP Series
Hydraulic Design Centrifugal Flow / Mixed Flow / Axial Flow
Construction Vertical Multi-Stage Turbine Pump
Installation Type Wet Pit / Deep Well / Open Sump Installation
Shaft Arrangement Long Vertical Line Shaft
Drive Type Electric Motor, Diesel Engine, or Gear Drive
Impeller Type Enclosed, Semi-Open, Mixed Flow, or Axial Flow Impeller
Bowl Assembly Single or Multiple Bowl Stages
Lubrication Water Lubricated or Oil Lubricated Line Shaft Bearings
Rotation Direction Clockwise (Viewed from Driver End)
Applications Municipal Water Supply, Irrigation, Flood Control, Cooling Water Systems, Fire Protection, Power Plants, Mining, Desalination Plants, Seawater Intake
Flow Capacity 20 – 70,000 m³/h
Head Range 3 – 400 m
Pump Diameter DN150 – DN2800
Speed Range 370 – 2,980 rpm
Maximum Efficiency Up to 88%
Maximum Working Pressure Depends on stage configuration
Bowl Stages Single Stage to Multi-Stage
NPSH Performance Excellent anti-cavitation performance
Maximum Submergence Depth Customized according to application
Temperature Range 0°C – 80°C (standard)
Motor Type Vertical Hollow Shaft Motor (VHS)
Alternative Drive Vertical Solid Shaft Motor (VSS)
Power Range 3 – 4,500 kW
Frequency 50 Hz / 60 Hz
Voltage Options 380V, 400V, 415V, 690V, 3.3kV, 6kV, 10kV
Protection Class IP55 / IP56 / IP65
Insulation Class Class F or H
Cooling Method TEFC / Air-Cooled
Duty Rating Continuous Duty (S1)
Starting Method DOL, Soft Starter, VFD
Bearing Arrangement Heavy-Duty Thrust Bearing
Coupling Type Direct Drive
Discharge Head Cast Iron / Carbon Steel
Column Pipe Carbon Steel
Bowl Assembly Cast Iron
Impeller Bronze
Pump Shaft Stainless Steel 420
Shaft Sleeve Bronze
Wear Ring Bronze
Bearings Rubber / Bronze Bearings
Fasteners Stainless Steel
Liquid Type Clean Water, Raw Water, River Water, Seawater, Industrial Water
Maximum Liquid Temperature 80°C Standard
Optional Temperature Range Up to 120°C (Special Design)
pH Range 5 – 11 (Depending on Materials)
Solids Content Low Solids Service
Installation Environment Deep Wells, Wet Pits, Intake Structures
Continuous Operation Yes
Corrosive Service Available with Stainless Steel or Duplex Materials
Seawater Service Available
Flood Control Applications Suitable
Pump Diameter DN150 – DN2800
Discharge Connection Flanged
Flange Standards ANSI, DIN, ISO, AWWA
Discharge Orientation Above-Ground or Below-Ground Discharge
Column Length Modular Sections (Customized)
Shaft Type Open Line Shaft or Enclosed Line Shaft
Installation Type Wet Pit, Can-Type, Barrel-Type
Baseplate Type Fabricated Steel Base
Coupling Type Vertical Motor Coupling
Suction Arrangement Bell Mouth Intake
Pump Setting Depth Customized According to Water Level
Scroll to Top